Specifications
LenzeBrand
Lenze
Series
8400 HighLine
Line
HighLine C
Unit type
Frequency inverter (cabinet)
Device type
Drive
Voltage range
3/PE AC 400/500 V
Rated current
23.5/18.8
Rated power
11.0
Typical application
Higher-power cabinet inverter for robust speed control and simple positioning.
DC link capacitors; power stage; fan/airflow issues; control PSU; IO/fieldbus module.
Details
- Brand: Lenze
- Series: 8400 HighLine
- Line: HighLine C
- Unit type: Frequency inverter (cabinet)
- Device type: Drive
- Voltage range: 3/PE AC 400/500 V
- Rated current: 23.5/18.8
- Rated power: 11.0
- Typical application: Higher-power cabinet inverter for robust speed control and simple positioning.
Common failures
DC link capacitors; power stage; fan/airflow issues; control PSU; IO/fieldbus module.